How to Read an FRP Grating Load-Span Table (Without Getting It Wrong)
A load-span table is the most important single document in a grating purchase — and the most commonly misread. Here is the four-step method.
Step 1: know your span — the real one
Span means the clear distance between supports, measured on site or from the structural drawings. If your supports are at 1.2 m centres and the bearer is 100 mm wide, your clear span is about 1.1 m — and you must read the table at 1.1 m, not 1.2. Reading at the wrong span is the number-one error: capacity falls with roughly the fourth power of span, so a 20 % span error swings allowable load by a factor of two.
Step 2: choose your load type
Tables list two families of numbers. UDL (uniformly distributed load) models crowds, stored materials, snow. Concentrated load models a wheel, a footfall at a panel edge, or a pallet corner — expressed in kN on a defined patch (usually 100 × 100 mm or 250 × 250 mm; the table states which). A deck can pass UDL and fail concentrated — check both against your reality.
Step 3: respect the deflection limit
The allowable load is tied to a deflection limit, because “not broken” is not the same as “acceptable underfoot”:
- L/180 — the standard industrial walkway criterion (a 1 m span may deflect ~5.5 mm)
- L/100 — a firmer criterion used for equipment platforms and public areas (some tables list it as a higher allowable load)
- L/250 or tighter — specified where machines or conveyors sit on the deck
A panel that “passes” at L/100 but fails L/180 will carry the load — it will just feel springy and look wrong. Specify the limit your application needs.
Step 4: confirm the table matches the panel
Generic tables describe a generic panel. Insist that the load table supplied with your quote is for the delivered panel — depth, mesh, resin and surface — and that it is signed. JINGLUE issues panel-specific tables with every quotation; that is what the specification-guide clauses are for.
For a quick check, use the interactive calculator — it applies exactly this logic.
FAQ: snow and ponded-water loads
How do I convert snow into a UDL I can compare against the table's allowable load?
Two steps. First, get the load: fresh snow is roughly 0.8–1.0 kN/m³, so a 0.5 m snowpack is about 0.4–0.5 kN/m² (≈ 8–10 psf); packed, wet or drifted snow can reach 2–3 kN/m³ and triple that figure. In practice, don't estimate from depth — use the regional code value (ASCE 7 ground snow load, EN 1991-1-3 snow zone), which already embeds density and drift factors. Second, combine correctly: snow plus dead load alone often governs for light-duty walkways at long spans, while most codes allow the governing-of combination between snow and full maintenance live load rather than both at 100 %.
What about water ponding?
Blocked mesh (icing, debris, leaves) converts open grating into a shallow tank — and water is the heaviest load a walkway ever realistically sees: every 100 mm of ponded depth adds ≈ 1.0 kN/m² (20.9 psf), more than most pedestrian live loads. Two mitigations: keep bearing spacing short enough that a 100–150 mm blocked-water head stays inside the table's allowable load, and specify a lifting-clip layout so covers can be cleared without tools. For grating used as sump and trench covers, check the pump-failure scenario explicitly — full submergence head, not design flow.